Visionix Retinomax Series

SGD 0.00

Retinomax products offer a wide range of refraction and keratometry measurements with high mobility, stability and accuracy, that have been recognized worlwide for years.

Handheld Auto Refractometer

  • Retinomax 5

  • Retinomax Screeen

Handheld Auto Refractometer & Keratometer

  • Retinomax K+5

  • Retinomax K+ Screeen

Add To Cart

Retinomax products offer a wide range of refraction and keratometry measurements with high mobility, stability and accuracy, that have been recognized worlwide for years.

Handheld Auto Refractometer

  • Retinomax 5

  • Retinomax Screeen

Handheld Auto Refractometer & Keratometer

  • Retinomax K+5

  • Retinomax K+ Screeen

Retinomax products offer a wide range of refraction and keratometry measurements with high mobility, stability and accuracy, that have been recognized worlwide for years.

Handheld Auto Refractometer

  • Retinomax 5

  • Retinomax Screeen

Handheld Auto Refractometer & Keratometer

  • Retinomax K+5

  • Retinomax K+ Screeen

  • Automatic Axis Compensation and Extended Measurement Range

    Not only does the device let the examiner know the cylinder axis angle, but it also adjusts automatically if it is not level. Regardless of the inclination of the device, the internal gyroscope gives the degree of inclination generated. The measuring range has also been extended.

    Fast and Reliable Measurement

    With the Retinomax 5 measurement process takes only 0.14 seconds. The pupil size is automatically measured, displayed, and printed. The measurement is done five times. If the data is unstable, the system will automatically retry 3 times in order to get the most stable result.

    Small Pupils

    The fixation intensity is automatically lowered for small pupils. The minimum pupil size for measurement is 2.3mm. If a pupil is smaller than 3.0 mm, the fixation target intensity will automatically be reduced by about 45% to avoid pupil contraction.

    New Child Mode

    While the measurement is being taken, a melody continually plays to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.

    View Finder

    Retinomax 5 enables view finder observation, there’s no limit to operator age. Diopter adjustable range is +/-8D. View finder arm angle is changeable from 0-135 degrees, making measurement easy regardless of patient’s position or posture.

  • Automatic Axis Compensation and Extended Measurement Range

    Not only does the device let the examiner know the cylinder axis angle, but it also adjusts automatically if it is not level. Regardless of the inclination of the device, the internal gyroscope gives the degree of inclination generated. The measuring range has also been extended.

    Fast and Reliable Measurement

    The measurement process takes only 0.14 seconds. The pupil size is automatically measured, displayed, and printed. The measurement is done five times. If the data is unstable, the system will automatically retry 3 times in order to get the most stable result.

    Small Pupils

    The fixation intensity is automatically lowered for small pupils. The minimum pupil size for measurement is 2.3mm. If a pupil is smaller than 3.0 mm, the fixation target intensity will automatically be reduced by about 45% to avoid pupil contraction.

    New Child Mode

    While the measurement is being taken, a melody continually plays to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.

    Upward-Tilting LCD

    The low-reflection 3.5-inch monitor, featuring a tilting screen with a 100-degree seamless range of motion allows both new as well as existing Retinomax users to easily adapt to Retinomax Screeen’s user-friendly design.

  • Automatic Axis Compensation and Extended Measurement Range

    Not only does the device let the examiner know the cylinder axis angle, but it also adjusts automatically if it is not level. Regardless of the inclination of the device, the internal gyroscope gives the degree of inclination generated. The measuring range has also been extended.

    Fast and Reliable Measurement

    Record acquisition time of 0.124 seconds. The Retinomax K-plus 5 is a portable auto-refractometer-keratometer that offers high and globally recognized accuracy. It is ideal for eyecare professionals looking to enhance the quality of vision examinations for their patients.

    Guaranteed Reliable Results. The Retinomax K-plus 5 features an automatic measurement system that repeats measurements if the data is not stable. This ensures reliable results, even for patients with small pupils or sensitivity to light.

    Small Pupils

    The fixation intensity is automatically lowered for small pupils. The minimum pupil size for measurement is 2.3mm. If a pupil is smaller than 3.0 mm, the fixation target intensity will automatically be reduced by about 45% to avoid pupil contraction.

    New Child Mode

    While the measurement is being taken, a melody continually plays to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.

    View Finder

    The Retinomax K-plus 5 is a portable auto-refractometer-keratometer that offers high and globally recognized accuracy. It is ideal for eyecare professionals looking to enhance the quality of vision examinations for their patients. The Retinomax K-plus 5 is the perfect device for professionals of all ages. The viewfinder observation allows for precise and reliable measurements, independent of the operator’s visual acuity. The adjustable diopter range of +/-8D enables the adaptation of the device to a wide range of patients. The tilting of the viewfinder arm, adjustable from 0 to 135 degrees, facilitates measurements regardless of the patient’s position or posture.

  • Automatic Axis Compensation and Extended Measurement Range

    Not only does the device let the examiner know the cylinder axis angle, but it also adjusts automatically if it is not level. Regardless of the inclination of the device, the internal gyroscope gives the degree of inclination generated. The measuring range has also been extended.

    Fast and Reliable Measurement

    The Retinomax K+Screeen has an acquisition time of only 0.124 seconds per measurement, ensuring you a quick and precise result. The measurement process automatically repeats if the data is not stable, guaranteeing you a reliable outcome.

    Small Pupils

    The fixation intensity is automatically lowered for small pupils. The minimum pupil size for measurement is 2.3mm. If a pupil is smaller than 3.0 mm, the fixation target intensity will automatically be reduced by about 45% to avoid pupil contraction.

    New Child Mode

    While the measurement is being taken, a melody continually plays to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.

    Upward-Tilting LCD

    The low-reflection 3.5-inch monitor, featuring a tilting screen with a 100-degree seamless range of motion allows both new as well as existing Retinomax users to easily adapt to Retinomax Screeen’s user-friendly design.

 

Enquire Now